Juxtapapillary duodenal diverticular bezor as an exceptional cause of biliary stent obstruction. Case report.

2007

INTRODUCTION: we describe the first case in literature of biliary stent obstruction by bezoar impaction in a iuxtapapillary duodenal diverticulum. CASE REPORT: this case illustrates an juxtapapillary duodenal diverticulum and bezoar in it causing obstructive jaundice in subject with two biliary stents for cholangiocarcinoma (Klatskin's tumor) in the absence of bile duct stones. RESULT: successful treatment with endoscopic stent removal and diverticulum toilette. Obstructive jaundice was cured after endoscopic removal of the bezoar and stent substitution. DISCUSSION: the presence of a bezoar and its possible contribution to the pathogenesis of pancreatitis in the presence of periampullary ex…

BezoarsMaleDiverticulumJaundice ObstructiveHumansStentsDuodenal Diseasesaged bezoar diverticulosis duodenum disease obstructive jaundice prosthesis failure stentAgedProsthesis FailureIl Giornale di chirurgia
researchProduct

Collected World Experience About the Performance of the Snorkel/Chimney Endovascular Technique in the Treatment of Complex Aortic Pathologies

2015

OBJECTIVES: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. BACKGROUND: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). METHODS: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. RESULTS: A total of 119 patients in US centers and 398 in European centers …

RegistrieMalemedicine.medical_treatmentKaplan-Meier EstimateGlobal HealthSettore MED/22 - Chirurgia VascolareSeverity of Illness IndexEndovascular aneurysm repairAortic aneurysmRetrospective StudieStentRegistriesAbdominal aortic aneurysm; Endovascular; Fenestrated; Thoracoabdominal; Vascular; Aortic Aneurysm Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Follow-Up Studies; Global Health; Humans; Kaplan-Meier Estimate; Male; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Stents; Survival Rate; Treatment Outcome; United States; Blood Vessel Prosthesis; RegistriesEndovascularmedicine.diagnostic_testMedicine (all)Endovascular ProceduresAbdominal aortic aneurysmAortic AneurysmProsthesis FailureEuropeSurvival RateBlood Vessel ProsthesiTreatment OutcomeFemaleStentsHumanUnited Statemedicine.medical_specialtyAortographyProsthesis DesignAortographyRisk AssessmentFenestratedFollow-Up StudieBlood Vessel Prosthesis ImplantationBlood vessel prosthesisVascularmedicineHumansAbdominalSurvival rateRetrospective StudiesEndovascular Procedurebusiness.industryRetrospective cohort studymedicine.diseaseUnited StatesBlood Vessel ProsthesisSurgeryAbdominal aortic aneurysm; Endovascular; Fenestrated; Thoracoabdominal; Vascular; Aortic Aneurysm Abdominal; Aortography; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Europe; Female; Follow-Up Studies; Global Health; Humans; Kaplan-Meier Estimate; Male; Prosthesis Design; Prosthesis Failure; Retrospective Studies; Risk Assessment; Severity of Illness Index; Stents; Survival Rate; Treatment Outcome; United States; Blood Vessel Prosthesis; Registries; Surgery; Medicine (all)Abdominal aortic aneurysmSurgeryThoracoabdominalbusinessAortic Aneurysm AbdominalFollow-Up StudiesAbdominal surgeryAnnals of Surgery
researchProduct

Biologic response of inguinal hernia prosthetics: a comparative study of conventional static meshes versus 3D dynamic implants.

2015

Despite improvements in prosthetics and surgical techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars-typical results with conventional static implants and plugs-may contribute to these adverse events. Recently, a new type of 3D dynamically responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic response be…

Sampling StudieTime FactorsTime FactorProstheses and ImplantBiomedical EngineeringMedicine (miscellaneous)BioengineeringBiocompatible MaterialsHernia InguinalPolypropylenesProsthesis DesignSampling StudiesStatistics NonparametricImaging Three-DimensionalProstheseTensile StrengthMaterials TestingHumansHerniorrhaphyBiocompatible MaterialMedicine (all)Inguinal herniaImplantTissue scaffoldProstheses and ImplantsSurgical MeshBiomaterialImmunohistochemistryProsthesis FailureSettore MED/18 - Chirurgia GeneraleTissue regenerationBiomaterials; Herniorrhaphy; Implants; Inguinal hernia; Prostheses; Tissue regeneration; Tissue scaffolds; Biocompatible Materials; Hernia Inguinal; Herniorrhaphy; Humans; Imaging Three-Dimensional; Immunohistochemistry; Materials Testing; Polypropylenes; Prosthesis Design; Prosthesis Failure; Sampling Studies; Statistics Nonparametric; Tensile Strength; Time Factors; Prostheses and Implants; Surgical Mesh; Biomaterials; Biomedical Engineering; Bioengineering; Medicine (miscellaneous); Medicine (all)PolypropyleneHumanArtificial organs
researchProduct

A ten-year follow-up of the Reflection cementless acetabular component.

2008

We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…

musculoskeletal diseasesAdultmedicine.medical_specialtyAcetabulum; Adult; Aged; Aged 80 and over; Arthroplasty Replacement Hip; Bone Cements; Equipment Failure Analysis; Follow-Up Studies; Hip Joint; Humans; Middle Aged; Osteoarthritis Hip; Prosthesis Design; Prosthesis Failure; Statistics as Topic; Time Factors; Hip ProsthesisTime FactorsArthroplasty Replacement HipStatistics as TopicProsthesis DesignOsteoarthritis HipmedicineHumansOrthopedics and Sports MedicineSurvival analysisPelvisFixation (histology)AgedAged 80 and overbusiness.industryBone CementsAcetabulumMiddle AgedConfidence intervalSurgeryProsthesis FailureEquipment Failure AnalysisReflection acetabular component hipmedicine.anatomical_structureAcetabular componentRadiological weaponCohortOrthopedic surgerySurgeryHip JointHip ProsthesisbusinessFollow-Up StudiesThe Journal of bone and joint surgery. British volume