Search results for " prosthesis failure"
showing 4 items of 4 documents
Juxtapapillary duodenal diverticular bezor as an exceptional cause of biliary stent obstruction. Case report.
2007
INTRODUCTION: we describe the first case in literature of biliary stent obstruction by bezoar impaction in a iuxtapapillary duodenal diverticulum. CASE REPORT: this case illustrates an juxtapapillary duodenal diverticulum and bezoar in it causing obstructive jaundice in subject with two biliary stents for cholangiocarcinoma (Klatskin's tumor) in the absence of bile duct stones. RESULT: successful treatment with endoscopic stent removal and diverticulum toilette. Obstructive jaundice was cured after endoscopic removal of the bezoar and stent substitution. DISCUSSION: the presence of a bezoar and its possible contribution to the pathogenesis of pancreatitis in the presence of periampullary ex…
Collected World Experience About the Performance of the Snorkel/Chimney Endovascular Technique in the Treatment of Complex Aortic Pathologies
2015
OBJECTIVES: We sought to analyze the collected worldwide experience with use of snorkel/chimney endovascular aneurysm repair (EVAR) for complex abdominal aneurysm treatment. BACKGROUND: EVAR has largely replaced open surgery worldwide for anatomically suitable aortic aneurysms. Lack of availability of fenestrated and branched devices has encouraged an alternative strategy utilizing parallel or snorkel/chimney grafts (ch-EVAR). METHODS: Clinical and radiographic information was retrospectively reviewed and analyzed on 517 patients treated by ch-EVAR from 2008 from 2014 by prearranged defined and documented protocols. RESULTS: A total of 119 patients in US centers and 398 in European centers …
Biologic response of inguinal hernia prosthetics: a comparative study of conventional static meshes versus 3D dynamic implants.
2015
Despite improvements in prosthetics and surgical techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars-typical results with conventional static implants and plugs-may contribute to these adverse events. Recently, a new type of 3D dynamically responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic response be…
A ten-year follow-up of the Reflection cementless acetabular component.
2008
We reviewed the long-term results at ten to 12 years of 118 total hip replacements in 109 patients using a second-generation hemispherical cementless acetabular component (Reflection) designed to address the problem of backside wear. Five patients (five hips) died and six patients (seven hips) were lost to follow-up. The remaining 98 patients (106 hips) had a mean age of 62.9 years (34.0 to 86.2) A rate of revision for aseptic loosening of 0.9%, and predictable results were found with respect to radiological evidence of fixation, lack of pain, walking ability, range of movement and function. One component was revised for aseptic loosening, and of the 101 hips (95.2%) that did not have a rev…